Technique Categories



Product Listing

  • Product Part
    Description:

    Highly polar phase; biscyanopropyl polysiloxane—not bonded Stationary phase selectivity optimized for isomer separation to ensure accurate quantification of critical cis/trans FAMEs. Application-specific QC test guarantees consistent, reliable performance for AOAC 996.06 and AOCS Ce 1j-07 methods. Excellent sample capacity; no peak distortion means easy, accurate peak integration. Similar phases: HP-88, CP Sil 88, SBP-2560, Rt-2560

    OUT OF STOCK

    Highly polar phase; biscyanopropyl polysiloxane—not bonded Stationary phase selectivity optimized for isomer separation to ensure accurate quantification of critical cis/trans FAMEs. Application-specific QC test guarantees consistent, reliable performance for AOAC 996.06 and AOCS Ce 1j-07 methods. Excellent sample capacity; no peak distortion means easy, accurate peak integration. Similar phases: HP-88, CP Sil 88, SBP-2560, Rt-2560

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

    OUT OF STOCK

    Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane General -purpose columns for drugs, solvent impur i t ies, pesticides,hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles. Equivalent to USP G27 and G36 phases. Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5, Rtx-5

  • Product Part
    Description:

    Fast analysis times and sharp mono-, di-, and triglyceride peaks. Stable at 430 °C for reliable, consistent performance. Similar phase: MET-Biodiesel, MXT Biodiesel TG, ZB-Bioethanol

    OUT OF STOCK

    Fast analysis times and sharp mono-, di-, and triglyceride peaks. Stable at 430 °C for reliable, consistent performance. Similar phase: MET-Biodiesel, MXT Biodiesel TG, ZB-Bioethanol

  • Product Part
    Description:

    Na2SO4 deactivation Acetylene and propadiene elute after butanes. Best separation for butene isomers (impurities in butene streams). Methyl acetylene elutes after 1,3-butadiene. Cyclopropane (impurity in propylene) elutes well before propylene. Temp. range up to 200 °C Similar phases: GS-ALUMINA, CP-Al2O3/Na2SO4, Alumina sulfate PLOT, Rt-Alumina BOND/Na2SO4

    OUT OF STOCK

    Na2SO4 deactivation Acetylene and propadiene elute after butanes. Best separation for butene isomers (impurities in butene streams). Methyl acetylene elutes after 1,3-butadiene. Cyclopropane (impurity in propylene) elutes well before propylene. Temp. range up to 200 °C Similar phases: GS-ALUMINA, CP-Al2O3/Na2SO4, Alumina sulfate PLOT, Rt-Alumina BOND/Na2SO4

  • Product Part
    Description:

    Low-polarity phase: Crossbond™ silarylene phase 1,4-bis(dimethylsiloxy) phenylene dimethyl polysiloxane Engineered to be a low-bleed GCMS column. Excellent inertness for active compounds. General-purpose columns—ideal for GCMS analysis of semi-volatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons. Similar phases: DB-5ms UI, DB-5ms, VF-5ms, SLB-5ms

    OUT OF STOCK

    Low-polarity phase: Crossbond™ silarylene phase 1,4-bis(dimethylsiloxy) phenylene dimethyl polysiloxane Engineered to be a low-bleed GCMS column. Excellent inertness for active compounds. General-purpose columns—ideal for GCMS analysis of semi-volatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons. Similar phases: DB-5ms UI, DB-5ms, VF-5ms, SLB-5ms

  • Product Part
    Description:

    SH-MetalX-1 Cap. Column 0.25mm, 0.1μm, 15m

    OUT OF STOCK

    SH-MetalX-1 Cap. Column 0.25mm, 0.1μm, 15m

  • Product Part
    Description:

    Tested with a comprehensive test mix to ensure high inertness. Useful for a wide range of applications. Use with most common solvents. Maximum temperature: 360 °C.

    OUT OF STOCK

    Tested with a comprehensive test mix to ensure high inertness. Useful for a wide range of applications. Use with most common solvents. Maximum temperature: 360 °C.

  • Product Part
    Description:

    Tested with a comprehensive test mix to ensure high inertness. Useful for a wide range of applications. Use with most common solvents. Maximum temperature: 360 °C.

    OUT OF STOCK

    Tested with a comprehensive test mix to ensure high inertness. Useful for a wide range of applications. Use with most common solvents. Maximum temperature: 360 °C.