LC.LCMS Accessories



Product Listing

  • Product Part
    Description:

    The male nut fitting used with Shim-pack XR-ODS can withstand pressures to 35 MPa. They cannot be used for the Shim-pack XR-ODS III column inlet. Replacement ferrule 228-45717-02

    The male nut fitting used with Shim-pack XR-ODS can withstand pressures to 35 MPa. They cannot be used for the Shim-pack XR-ODS III column inlet. Replacement ferrule 228-45717-02

  • Product Part
    Description:

    Zero dead volume design to prevent the spread of peaks. Double ended PEEK ferrule for connecting inlet/outlet tubing to columns. Use with knurled nut 228-45717-01.  

    LOW STOCK

    Zero dead volume design to prevent the spread of peaks. Double ended PEEK ferrule for connecting inlet/outlet tubing to columns. Use with knurled nut 228-45717-01.  

  • Product Part
    Description:

    Removes contaminants at the most upstream of HPLC system Does not affect system volume Available for LC/MS Internal Volume ~0.7mL Packing material Spherical Activated Carbon Replace once a year or after flowing for 60L The GLC Suction Filter 2 is the most upstream consumable part of a HPLC system and is useful for removing contaminants in the mobile phase. The product is easy to install and can be replaced by the user. Removal Effect of GLC Suction Filter 2 for LC/MS Removal of contaminants in the mobile phase by GLC Suction Filter 2 was evaluated. A mixture of acetonitrile and water (1/9, 5/5, 9/1) was used as the mobile phases. In all case, the removal of contaminants was confirmed and the noise level of the TIC was also reduced. Analytical Conditions Instruments : Nexera X2 Flow Rate : 0.2 mL /min Detection : MS (ESI), Scan Mode (100 to 2000 m/z , positive, negative)   Take note: The suction tube is not included. 3mm outer diameter suction tube can be connected. When using ion-pair reagents in the mobile phase, the ion-pair reagent is retained in the product, and retention time and peak shape may be affected. Bleed noise from this product may be seen. This product does not remove all impurities. If impurities are not retained, ghost peaks may be detected. In this case, replace the product.  

    LOW STOCK

    Removes contaminants at the most upstream of HPLC system Does not affect system volume Available for LC/MS Internal Volume ~0.7mL Packing material Spherical Activated Carbon Replace once a year or after flowing for 60L The GLC Suction Filter 2 is the most upstream consumable part of a HPLC system and is useful for removing contaminants in the mobile phase. The product is easy to install and can be replaced by the user. Removal Effect of GLC Suction Filter 2 for LC/MS Removal of contaminants in the mobile phase by GLC Suction Filter 2 was evaluated. A mixture of acetonitrile and water (1/9, 5/5, 9/1) was used as the mobile phases. In all case, the removal of contaminants was confirmed and the noise level of the TIC was also reduced. Analytical Conditions Instruments : Nexera X2 Flow Rate : 0.2 mL /min Detection : MS (ESI), Scan Mode (100 to 2000 m/z , positive, negative)   Take note: The suction tube is not included. 3mm outer diameter suction tube can be connected. When using ion-pair reagents in the mobile phase, the ion-pair reagent is retained in the product, and retention time and peak shape may be affected. Bleed noise from this product may be seen. This product does not remove all impurities. If impurities are not retained, ghost peaks may be detected. In this case, replace the product.  

  • Product Part
    Description:

    10 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

    LOW STOCK

    10 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

  • Product Part
    Description:

    25 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

    LOW STOCK

    25 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

  • Product Part
    Description:

    50 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

    LOW STOCK

    50 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

  • Product Part
    Description:

    100 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

    100 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

  • Product Part
    Description:

    250 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

    250 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

  • Product Part
    Description:

    500 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

    500 μL Fixed Needle Syringe for HPLC Manual Injectors Syringe Volume PTFE Tipped Plunger Needle Length (mm) Needle Gauge Needle OD Needle ID (mm) Needle Tipe Syringe Part Number 10 μL No 51 22 0.028" 0.17 LC 670-12554-01 25 μL No 51 22 0.028" 0.37 LC 670-12554-02 50 μL No 51 22 0.028" 0.37 LC 670-12554-03 100 μL No 51 22 0.028" 0.37 LC 670-12554-04 250 μL No 51 22 0.028" 0.37 LC 670-12554-05 500 μL No 51 22 0.028" 0.37 LC 670-12554-06  

  • Product Part
    Description:

    This Polymer Tubing Cutter provides the most accurate cut which enables leak free HPLC connection. It will provide a clean, burr free, 90 degree cut for your 1/16 or 1/8OD tubing.

    OUT OF STOCK

    This Polymer Tubing Cutter provides the most accurate cut which enables leak free HPLC connection. It will provide a clean, burr free, 90 degree cut for your 1/16 or 1/8OD tubing.